This content is intended for general information. The application must be carried out by means of equipment manufacturer instructions, the risk assessment specific to the business and the energy control procedure prepared by authorized persons.

Why do we need a special choice?

The battery can store dangerous pressure even after the pump is stopped, therefore, the cessation of electricity does not mean that hydraulic energy is controlled.

Data for the product selection

The type of battery, working pressure, isolation valve, emissions line, manometer and the position of moving loads are marked in the machine scheme. If there is no lockable valve and secure emissions point, engineering needs to be improved.

Control PointThe expected evidence
Nutrition of the pumpPersonal lock and label
The battery vanPhysical lock in closed position
Line pressureVerified Zero/Riskless Level
Mechanical loadApproved support or block

Order of Application

  1. Take the machine in a secure position and mechanically support the moving loads.
  2. Isolate the pump engine with electric lotus.
  3. Close the battery isolation valve and lock it with the appropriate product.
  4. Empty the tank in a pressure-controlled manner according to the manufacturer's procedure.
  5. With the manometer, test port and movement testing, confirm that energy is now removed.

Frequent mistakes

What should be sent to match the offer or product?

The brand-model of the equipment must be sent together, general and close plan photos in a safe state, millimeter measurements, energy type, number of people to work at the same time, and the usage environment. This information reduces the risk of choosing product code according to its appearance alone.

Select the right LOTO product together.

Share your photos and sizes; let us evaluate the product, procedure, training and simulator needs together.